Animal Waste & Poultry Waste Incinerators
Animal Waste Incinerator is applicable in various areas i.e. Slaughter Houses, Animal Farms, Research Institutes, Municipal Corporations, Abattoir, Veterinary Hospitals, Zoo etc and Poultry waste incinerator in Poultry Farms, Hatcheries, Poultry Processing Units, Small Animal Farms, Municipal Councils, Health Departments, Research Institutes etc.
Mobile Incinerator/Poultry Waste Incinerator
Power Source | Electric/Diesel/Gas |
Waste Type | Poultry/Animal/Birds waste |
Automatic Grade | Automatic/Manual |
Capacity | 10-100 kgs/hr |
Incinerator Type | Laboratory/Poultry/Animal Incinerator |
MOBILE INCINERATOR
Double chamber unit
Pre-configured and pre-tested
Plug & Play type
Low Emissions and low residual waste
Low running cost
Environment Friendly
Low Space requirement – compact design
Low maintenance
Esthetically pleasing looks
Electrical requirement: 220 v AC
Height of stack – 3 mtrs
Burners- Diesel fired/Gas Fired
Control Panel- Provided
Material of Construction of chambers- Heavy duty steel
Insulation & Refractories in chambers factory installed
Temperature up to 12000 can be achieved
Easy installation
Incinerator With Quencher, Venturi Scrubber & Packed Bed Scr
Automatic Grade | Automatic |
Incinerator Type | Laboratory Incinerator |
Waste Type | Hospital/Medical Waste |
Power Source | Electric |
Capacity | 0-10 kg/hr, 10-30 kg/hr |
INCINERATOR WITH QUENCHER, VENTURI SCRUBBER & PACKED BED SCRUBBER (3 STAGE SCRUBBERS)
Dual Chamber design
Material of Construction – Heavy duty steel
Insulated and Refractory lined chambers
Burners in various fuel options
Emergency stack to vent out the gases incase of power failure
Quencher to reduce the flue gas temperature
Venturi Scrubber high energy air pollution control device with Stainless Steel -316L Construction for cleaning of gases
Droplet Separator (for separation of water droplets from glue gases) cum re-circulation tank
Re-circulation pump
Packed Bed Scrubber for purification of gases
F D Fan for providing air inside primary and secondary chamber
I D Fan to maintain the negative draft and control the gas flow
Fuel Oil Tank & Piping
Electrical Control Panel
Interconnecting ducts & piping
Chimney of 5,10,15,30 mtrs height from ground level OR as per country’s regulation and client’s requirement
Low running & maintenance cost
Environment Friendly
Installation with the help of installation manual and drawings/By ATL’s engineer
Incinerator With Cyclone Separator
Usage/Application | Industrial |
Type | Magnetic Separator |
Automatic Grade | Automatic |
Incinerator Type | Laboratory Incinerator |
Waste Type | Hospital/Medical Waste |
Capacity | 0-10 kg/hr, 10-30 kg/hr |
Power Source | Electric |
INCINERATOR WITH CYCLONE SEPARATOR
Dual Chamber design
Material of Construction – Heavy duty steel
Insulated and Refractory lined chambers
Burners in various fuel options
Cyclone Separator for dust particle removal
Eductor system for reducing flue gas temperature
Eductor Fan for fresh air
F D Fan for inside air in primary and secondary chamber
Fuel Oil Tank & Piping
Electrical Control Panel
Interconnecting ducts
Chimney of 5 mtrs height from ground level OR as per client’s requirement
Low running cost
Environment Friendly
Installation easy with the help of installation manual and drawings
Incinerator With Cyclone Separator
Usage/Application | Industrial |
Automatic Grade | Automatic |
Incinerator Type | Laboratory Incinerator |
Waste Type | Hospital/Medical Waste |
Capacity | 0-10 kg/hr, 10-30 kg/hr |
Power Source | Electric |
- · Dual Chamber design
- Material of Construction – Heavy duty steel
- Insulated and Refractory lined chambers
- Burners in various fuel options
- Cyclone Separator for dust particle removal
- Eductor system for reducing flue gas temperature
- Eductor Fan for fresh air
- F D Fan for inside air in primary and secondary chamber
- Fuel Oil Tank & Piping
- Electrical Control Panel
- Interconnecting ducts
- Chimney of 5 mtrs height from ground level OR as per client’s requirement
- Low running cost
- Environment Friendly
- Installation easy with the help of installation manual and drawings
Incinerator With Cyclone Separator
Usage/Application | Industrial |
Automatic Grade | Automatic |
Incinerator Type | Laboratory Incinerator |
Waste Type | Hospital/Medical Waste |
Power Source | Electric |
Capacity | 0-10 kg/hr,10-30 kg/hr |
INCINERATOR WITH CYCLONE SEPARATOR
Dual Chamber design
Material of Construction – Heavy duty steel
Insulated and Refractory lined chambers
Burners in various fuel options
Cyclone Separator for dust particle removal
Eductor system for reducing flue gas temperature
Eductor Fan for fresh air
F D Fan for inside air in primary and secondary chamber
Fuel Oil Tank & Piping
Electrical Control Panel
Interconnecting ducts
Chimney of 5 mtrs height from ground level OR as per client’s requirement
Low running cost
Environment Friendly
Installation easy with the help of installation manual and drawings